Àåºñ¸í(¾à¾î) Fourier transform infrared spectroscopy (FT-IR)
¸ðµ¨¸í Nicolet iS50
ºê·£µå Theromo Fisher Scientific
À§Ä¡ ½Å¼ÒÀç°øÇаü 120È£
´ã´çÀÚ ÀÌÁø¿µ yk030501@hanyang.ac.kr
´ã´çÀÚ ÀüÈ­¹øÈ£ 02-2220-1387
±â±â»óÅ ¿¹¾à°¡´É
ÀμâÇϱâ¸ñ·ÏÀ¸·Î

¿ø¸®¿Í Ư¡

Àû¿Ü¼± ºöÀÇ ±¤ Èí±¤µµ ․ Åõ°úµµ¸¦ º½À¸·Î½á ½Ã·á°¡ °¡Áö°í ÀÖ´Â Àû¿Ü¼± ºö¿¡ ´ëÇÑ °íÀ¯ Áö¹®¿µ¿ª(Finger Print)À» ÀÌ¿ëÇÏ¿© À¯±â¹°, ¹«±âÈ­ÇÕ¹°, ¹ÝµµÃ¼ wafer, Æú¸®¸Ó µî Á¤¼º,Á¤·®ºÐ¼®°¡´É

»ç¾ç

1. Spectrometer

       1) Polaris High Stability, Long Lifetime Mid-IR Source : Standard

       2) Tungsten-Halogen Near-IR/Visible Source : Option

       3) Four Position Source Mirror : Option

       4) Continuously Variable Iris Aperture : Standard

       5) Gold Optical Coatings : Standard

       6) Aluminum Optical Coatings : Option

       7) DLaTGS Detector : Standard

       8) Three Position Detector Mirror : Option

       9) Attenuation Wheel : Standard

     10) Validation Wheel : Standard

     11) Automated Polarizer : Option

     12) Automated Filter Wheel : Option

     13) Automated Beamsplitter : Exchanger Option

     14) Automated Sample Compartment Purge Shutters : Option

 

2. Software

       1) OMNIC Software: Standard

 

3. External Beam Capabilities

       1) Dual Side External Beams : Option

       2) Collimated Emission Port : Option

       3) Focused Emission Port : Option

       4) Focused Emission Port : Option

       5) Side External Detector Port : Option

 

4. Performance Specifications

       1) Spectral Range, Standard System : 7800350 cm-1

       2) Spectral Range, CsI Optics : 6400200 cm-1

       3) Spectral Range, Multi-Range Optics : 27,00020 cm-1

       4) Optical Resolution, Mid-IR : Less than 0.09 cm-1

       5) Signal-to-Noise, 1 minute scan, Peak-to-Peak, 4 cm-1: 55,000:1

       6) Signal-to-Noise, 5 second scan, Peak-to-Peak, 4 cm-1: 13,000:1

       7) Ordinate Linearity : 0.07%T

       8) Wavenumber Precision : Better than 0.01 cm-1

       9) Scan Velocity (15 values) : 0.1586.28 cm/sec

     10) Rapid Scan, Spectra Per Second : 65 (at 16 cm-1), 95 (at 32 cm-1)

     11) MCT Dewar LN2 Hold Time : 18 Hours

 

5. iS50 ATR Module

       1) Crysta : Diamond

       2) Spectral Range : 500080 cm-1

       3) Down Force of Pressure Device : 60 lbs

       4) Detector Proprietary : DLaTGS

 

»ç¿ë·á

±âº»·á/30ºÐ(ATR»ç¿ëÆ÷ÇÔ)-20,000¿ø