HANYANG UNIVERSITYº¸À¯±â±â

º¸À¯±â±â¸®½ºÆ®

Ȩ  >  º¸À¯±â±â¸®½ºÆ®  >  º¸À¯±â±â¸®½ºÆ®
È­ÇÕ¹°Àüó¸®/ºÐ¼®Àåºñ
±¤ÇÐ/ÀüÀÚ¿µ»óÀåºñ
¹°¸®ÀûÃøÁ¤Àåºñ
À¯µµ°áÇÕÇöóÁ Áú·®ºÐ¼®±â
À¯µµ°áÇÕÇöóÁ Áú·®ºÐ¼®±â
±â±â ¼³¸í
Àåºñ¸í(¾à¾î) Inductively Coupled Plasma - Mass Spectrometry (ICP-MS)
¸ðµ¨¸í iCAP RQ
ºê·£µå Thermo Fisher Scientific
À§Ä¡ ½Å¼ÒÀç°øÇаü 121È£
´ã´çÀÚ ÀÌÁö¿¬ jiyeon1234@hanyang.ac.kr
´ã´çÀÚ ÀüÈ­¹øÈ£ 02-2220-2756
±â±â»óÅ ¿¹¾à °¡´É
ÀμâÇϱâ¸ñ·ÏÀ¸·Î

¿ø¸®¿Í Ư¡

ICP-MS´Â ¿øÀÚÀÇ °íÀ¯ÇÑ Áú·® Â÷À̸¦ ÀÌ¿ëÇÑ ±Ø¹Ì·® ¹«±â ¿ø¼Ò ºÐ¼®Àåºñ À̸ç, ICP-OES¿Í µ¿ÀÏÇÑ °í¿ÂÀÇ ÇöóÁ¼Ò½º¸¦ ÀÌ¿ëÇÏ¿©, 

¿øÀÚÈ­ ½ÃŲ ¹°ÁúÀÇ ºûÀ» ºÐ¼®ÇÏ´Â ºÐ±¤ºÐ¼®±â¿Í ´Þ¸® ÇöóÁ·Î ºÎÅÍ ¿øÀÚÈ­µÈ ¹°ÁúÀº Áú·®ÇÊÅÍÀλçÁß±ØÀÚ¸¦Åë°ú¸¦ ÇÏ¿© °ËÃâ±â¿¡

µµ´ÞÇÏ°Ô µÇ¸ç, ÀÌ ¶§ °ËÃâ±â±îÁö µµ´ÞÇÏ´Â ¹°ÁúÀÇ ÈûÀº Àü±âÀû ½ÅÈ£·Î Àü´ÞµÇ°í µµ´ÞÇÑ ¹°ÁúÀº m/z (Áú·® ´ë ÀüÇϺñ)¸¦ ÀÌ¿ëÇÏ¿©

¹°ÁúÀÇ ±Ø¹Ì·®¹«±â¿ø¼ÒÀǼººÐÀ» ºÐ¼®ÇÒ ¼ö ÀÖ½À´Ï´Ù.

»ç¾ç

1. Sample introduction

     1) Peristaltic pump

       - Sofrware controlled 12 roller, 4channel mini pump
     2) Spray chamber

       - Baffled cyclonic, high purity quartz, PFA spary chamber

     3) Peltier cooler

       - Software control in range -10¡ÆC to +20¡ÆC

 

2. Plasma ion source

     1) RF generator

       - Digital, solid state RF generator, ~27MHz

       - RF power range : 400W to 1600W (default hot plasma power 1550W)

     2) Addition mass flow controllers

      - Capacity for two further MFCs for gas, dilution 

     3) Plasma TV

      - HD camera for remote monitering of plasma status

 

3. Ion optics

     1) RAPID lens

      - 90¢ª ion lens operating at a single fixed voltage

 

4. Collision / Reaction Cell

     1) QCell

       - Non-consumable, zero maintenance

       - Automatic low mass cut off

     2) Standard MFC

       - Pure He collision gas
     3) Optional MFC

       - Reaction gas mixtures : O2, NH3/He, H2/He
 

5. Quadrupole Mass Analyzer  

     1) Field

       - Virtual hyperbolic

     2) Mass range 

       - 2-290 u

     3) Abundance sensitivity

       - <0.5 ppm at m-1 (m= 238U)

 

6. Ion Detection System  

     1) Detector

       - Dual mode discrete dynode electron multiplier

       - Simultaneous pulse/analog over four orders of magnitube

     2) Minimum dwell time 

       - 100us in pulse and analog

»ç¿ë·á

Ç׸ñ¸í

´ÜÀ§¸í

´Ü°¡ [¿ø]

Àüó¸® ½ÃÇè (´ã´çÀÚ »ó´ã ÈÄ ÁøÇà)

½Ã·á

20,000

±âº» ºÐ¼®

±âº»·á (1°³ ¿ø¼Ò)

10,000

¿ø¼Ò Ãß°¡

¿ø¼Ò/½Ã·á (2°³ ¿ø¼Ò ÀÌ»ó ºÎÅÍ)

5,000

Àü¿ø¼Ò ºÐ¼®

½Ã·á

150,000

±Ø¹Ì·® ºÐ¼® (¹ÝµµÃ¼ ½Ã·á)

*´ã´çÀÚ ÇùÀÇ ÈÄ ÁøÇà*

½Ã·á

300,000

VAT º°µµ