Áú·®±â¹Ý À¯¼¼Æ÷ºÐ¼®±â [Mass Cytometry]
Áú·®±â¹Ý À¯¼¼Æ÷ºÐ¼®±â [Mass Cytometry]
±â±â ¼³¸í
Àåºñ¸í(¾à¾î) CyTOF(Cytometry by time of flight)
¸ðµ¨¸í Helios
ºê·£µå Fluidigm
À§Ä¡ ÀÚ¿¬°úÇаü 623È£ [Â÷¼¼´ë À¯¼¼Æ÷ºÐ¼® ¿¬±¸¼¾ÅÍ]
´ã´çÀÚ ±Ç¼÷Áø gwon1955@hanyang.ac.kr
´ã´çÀÚ ÀüÈ­¹øÈ£ 02-2220-4594
±â±â»óÅ ´ã´çÀÚ ¹®ÀÇ ÈÄ ¿¹¾à °¡´É [Æ÷Åп¹¾à X]
ÀμâÇϱâ¸ñ·ÏÀ¸·Î

¿ø¸®¿Í Ư¡

- Áú·®±â¹Ý À¯¼¼Æ÷ºÐ¼®±â(Mass Cytometry)´Â °¢°¢ÀÇ ¼¼Æ÷¿¡ ´ëÇØ 40°³ ÀÌ»óÀÇ ´Ù¸¥ Ç×üÁ¤º¸µéÀ» µ¿½Ã¿¡ ÃøÁ¤ÇÔÀ¸·Î½á °¢ ¼¼Æ÷ÀÇ Ç¥ÇöÇü, ½ÅÈ£Àü´Þ °æ·Î ¹× ±â´É¿¡ ´ëÇؼ­ º¸´Ù Æ÷°ýÀûÀ¸·Î ÀÌÇØÇÒ ¼ö ÀÖ´Â °íÂ÷¿ø, ´ë¿ë·®ÀÇ µ¥ÀÌÅ͸¦ Á¦°øÇÔ.

 

- ÇöÀç ±âÃÊ »ý¸í°úÇבּ¸»Ó¸¸ ¾Æ´Ï¶ó ÀÓ»ó¿¡¼­ °Ç°­°ËÁø ¹× Áúº´Áø´ÜÀ» À§ÇØ ±¤¹üÀ§ÇÏ°Ô »ç¿ëµÇ°í ÀÖ´Â, ±âÁ¸ÀÇ Çü±¤±â¹Ý À¯¼¼Æ÷ºÐ¼®¹ý(Fluorescence-based Flow Cytometry)Àº ´ÜÀϼ¼Æ÷¼öÁØ¿¡¼­ÀÇ ´Ù¾çÇÑ Á¤º¸¸¦ Á¦°øÇÏ´Â ¸Å¿ì ¿ì¼öÇÑ ¹ÙÀÌ¿À/ÀÇ·á ºÐ¼®ÀåºñÀÌÁö¸¸, ¼­·Î ´Ù¸¥ Çü±¤ ½ÅÈ£µé °£ÀÇ Áßø ¹®Á¦(spillover)·Î ÀÎÇÏ¿© °¢ ¼¼Æ÷·Î ºÎÅÍ ¾òÀ» ¼ö ÀÖ´Â Á¤º¸ÀÇ ¼ö(»ê¶õ/Çü±¤ ä³ÎÀÇ ¼ö)°¡ Á¦ÇÑÀû(ÀϹÝÀûÀ¸·Î 5-10°³ ä³Î ÀÌÇÏ)ÀÎ ´ÜÁ¡ÀÌ ÀÖÀ½.

 

- ÀÌ¿¡ ºñÇÏ¿© Áú·®±â¹Ý À¯¼¼Æ÷ºÐ¼®±â(Mass Cytomerty)´Â Çü±¤ ºÐÀÚ ´ë½Å ÁÖ·Î ¶õźÁ· ±Ý¼ÓÀÌ Ç¥ÁöµÈ Ç×ü¸¦ »ç¿ëÇÏ°í, ÀÌµé ±Ý¼Ó¿ø¼Òµé°£ÀÇ Áú·® Â÷ÀÌ¿¡ ±â¹ÝÇÏ¿©, ¼¼Æ÷ÀÇ Ç¥¸é ¶Ç´Â ³»ºÎ¿¡ Á¸ÀçÇÏ´Â ¼ö¸¹Àº ´Ù¾çÇÑ Ç×üµéÀ» ´ÜÀϼ¼Æ÷ ¼öÁØ¿¡¼­ 1Da(1amu)ÀÇ Áú·®ºÐÇØ´ÉÀ¸·Î ÃøÁ¤ÇÔ. µû¶ó¼­, Ç×ü½ÅÈ£°£ÀÇ ÁßøÇö»óÀÌ ÃÖ¼ÒÈ­µÇ¾î °³º° ¼¼Æ÷´ç 30-50¿© ä³Î±îÁö Á¤º¸¸¦ ¾òÀ» ¼ö ÀÖÀ¸¸ç À̷κÎÅÍ ±âÁ¸ÀÇ Çü±¤±â¹Ý À¯¼¼Æ÷ ºÐ¼®¹ýÀÇ ÇѰ踦 ¶Ù¾î ³Ñ´Â °íÂ÷¿øÀÇ ´ë±Ô¸ð ´ÜÀϼ¼Æ÷ºÐ¼® µ¥ÀÌÅ͸¦ È®º¸ÇÒ ¼ö ÀÖÀ½.

 

- ¶ÇÇÑ Áú·®±â¹Ý À¯¼¼Æ÷ºÐ¼®±â´Â ¼¼Æ÷¿¡ °ÅÀÇ Á¸ÀçÇÏÁö ¾Ê´Â ÈñÅä·ù ¶õźÁ· ±Ý¼ÓµéÀ» Ç¥Áö¹°Áú·Î »ç¿ëÇϹǷΠ¹è°æ½ÅÈ£(background signal)ÀÇ ¼öÁØÀÌ ¸Å¿ì ³·°í, ÀÚ°¡Çü±¤(auto fluorescence)¹®Á¦µµ ÇØ°áµÇ¹Ç·Î, ¼¼Æ÷¿¡¼­ ¾ÆÁÖ ¹Ì·®À¸·Î Á¸ÀçÇÏ´Â Ç×ü½ÅÈ£µµ ºÐ¼®ÀÌ °¡´ÉÇÔ.

 

- Áú·®±â¹Ý À¯¼¼Æ÷ºÐ¼®±â ½ÇÇèÀ» À§ÇÏ¿© ÇÊ¿äÇÑ ±Ý¼ÓÇ¥Áö Ç×üµéÀº ÇöÀç 630Á¾·ù ÀÌ»óÀÌ »ó¾÷ÀûÀ¸·Î ÆǸŰ¡ µÇ°í ÀÖÀ¸¸ç, ¿¬±¸ÀÚ°¡ ÀÌ¹Ì º¸À¯ÇÏ°í Àְųª Ưº°È÷ ¿øÇÏ´Â Ç×ü¿¡ ±Ý¼ÓÇ¥Áö¸¦ ¿øÇÒ °æ¿ì 35°¡ÁöÀÇ µ¿À§¿ø¼ÒÁß¿¡¼­ ¼±ÅÃÇÏ¿© Á÷Á¢ Ç¥Áöµµ °¡´ÉÇÔ.

»ç¾ç

(1)  Channels : > 40

 

(2)  Mass range : 75 ~ 209 Da atomic analytical mass(135 channels)

 

(3)  Abundance sensitivity : 0.2% ~ 0.4% for 159Tb

 

(4)  Instrument response : < 600,000 counts/pg 159Tb

 

(5)  Detection limit : up to 350 antibodies/cell

 

(6)  Dynamic range : 3 ~ 5 orders of magnitude

 

(7)  Calibration : Automated

 

(8)  Peak throughput : > 1,000 events/sec

 

(9)  Flow rate : > 20 §¡/min

 

(10) Replicate sample CV (normalized) : < 3%

½Ã·áÁغñ¹æ¹ý

- ´ã´çÀÚ¿¡°Ô º°µµ ¹®ÀÇ

»ç¿ë·á

¡¡

Ç× ¸ñ

±³ ¿Ü

±³ ³»

ÃøÁ¤

±âº» (2½Ã°£)

600,000¿ø / ½Ã°£

300,000¿ø / ½Ã°£

Ãß°¡ ½Ã°£

200,000¿ø / ½Ã°£

100,000¿ø/ ½Ã°£

Çؼ®

µ¥ÀÌÅÍ ºÐ¼®

º°µµ ¹®ÀÇ

º°µµ ¹®ÀÇ

- ºÎ°¡¼¼ º°µµ
- Â÷¼¼´ëÀ¯¼¼Æ÷ºÐ¼®¼¾ÅÍ ¶Ç´Â Â÷¼¼´ë¼ÒÀçµðÀÚÀÎ ¿¬±¸¼Ò ¼Ò¼Ó ¿¬±¸¿ø/ȸ¿ø»ç´Â 50% Ãß°¡ ÇÒÀÎ

ºÐ¼®°á°úÇ¥Çö

 

[ SPADE Analysis of Mass Cytomery Data (Ha et al. (2019), Biorxiv, https://doi.org/10.1101/617332

 

 

 

 [ t-SNE Analysis of Mass Cytomery Data (Ha et al. (2019), Biorxiv, https://doi.org/10.1101/617332 ]